  • Technical Details:
  • Operating Voltage:   4.3V~6V
  • Rating Voltage:      6.5V(exceeding this value will cause permanent damage to the module)
  • Operating Current<80mA(Input voltage 5V)
  • Fingerprint Template      768 templates
  • Search Time<1.5s(200 fingerprint, average value in test)
  • Power-on Time<200ms(Time lapse between module power-on to module ready to receive instructions)
  • Tolerated Angle Offset±45°
  • User Flash Memory64KByte
  • Interface Protocol:    Standard serial interface(TTL level)
  • Communication Rate:    57600bps
  • Temperature: – 10℃~+40℃ Relative humidity: 40%RH~85%RH(no dew)
  • Module connected via: 4 PIN cable.

The PIN details
Fingerprint device

Fingerprint Model 360-datasheet

1. Power supply (+) 5V DC
2. Module Tx  – Open-drain output, need to use pull-up resistance in application (value 10KΩ)
3. Module Rx – Wide voltage input, 7V affordable
4. Power supply ( Gnd)
Name of Command Code
1.  Add fingerprint  – 0x40
2.  Delete fingerprint – 0x42
3.  Search fingerprint – 0x44
4.  Empty fingerprint database – 0x46
5.  Search information in fingerprint database – 0x4B
6.  Download fingerprint template  – 0x50
7.  Upload fingerprint template – 0x52
8.  Read ID number – 0x60
9.  Read user Flash – 0x62
10.  Write user Flash – 0x64
11.  Read product logo – 0x80
Name of Command Response Code

  • 1. Receive correct – 0x01
  • 2.  Receive error – 0x02
  • 3.  Operation successful – 0x31
  • 4.  Finger detected – 0x32
  • 5.  Time out – 0x33
  • 6.  Fingerprint process failure – 0x34
  • 7.  Parameter error – 0x35
  • 8.  Fingerprint matching with this ID found – 0x37
  • 9.  No matching fingerprint with this ID – 0x38
  • 10. Fingerprint found – 0x39
  • 11. Fingerprint unfound – 0x3A

                  Working
Module waits for command from HOST after it is powered on. Module will respond by a Rx correct packet after receiving the correct command. Module will perform operations according to the command and will return corresponding information after the operation is successful. When the Module is performing operation, it will not respond to other command given by HOST. If the check sum for the received command is wrong, the module will send back receive error response.

  • Module receive correct Data:  0x4D + 0x58 + 0x30 + 0x01 + 0x01 + 0xD7
  • Module receive error Data:      0x4D + 0x58 + 0x30 + 0x01 + 0x02 + 0xD8